Using the SVR5 ndcert test suites

NCARD test suite


Synopsis:
auto_ncard all

Configuration file:
nd-ncard.cfg

Test suite name:
nd-ncard

Summary:
Provides stress testing by running simultaneous send and receive operations on all cards. This should be run after the DRIVER STRESS test suite has stress tested the driver with one card configured. Additional stress testing should be done with the loadtests test suites.

Media types:
All

Init state:
1

Executing machine(s)
master and slave

Execution time:
About 5 minutes.

Number of test cases:
5

Number of invokable scenarios:
5

Configuration variables:

MASTERSLAVE
Set to master on the machine where the driver being tested is installed and to slave on the other machine.

MDIDRV
The name (prefix) of the driver being tested. This parameter is set only on the master machine, not on the slave machine.

DEVICE
Set both machines to /dev/net0.

TEST_SCENARIO
Specify the feature from the list below or set to all to run all tests.


© 2005 The SCO Group, Inc. All rights reserved.